| Swine |
DEVICE
ACCESS TO:
|
USAGE
|
IMPLANTED
SYSTEM
|
CATHETER
POLYURETHANE
(P) AND/OR
SILICONE (S)
|
NUMBER OF PUNCTURES WITH NEEDLE
|
COMMENTS
|
| VASCULAR |
JUGULAR
|
Delivery,
Sample
Collection,
Infuse,
Chronic/
Acute
|
XL-ISC-
|
(S) SPECIAL
|
2,000
|
Port & catheter are placed subcutaneous. For chronic & acute use. The port is placed behind the ear for easy access. See [*] below.
|
Delivery, Sample Collection, Infuse,
Acute
|
C9-58-90
|
(S) (P)
|
N/A
|
Catheter is percutaneous. For acute use only (up to 3 weeks). |
| VASCULAR |
CAROTID
|
Delivery,
Sample
Collection,
Infuse,
Chronic/
Acute
|
XL-ISC-
|
(S) SPECIAL
|
2,000
|
Port & catheter are placed subcutaneous. For chronic & acute use. The port is placed behind the ear for easy access. See [*] below. |
|
Acute
|
C9-58-90
|
(S) (P)
|
N/A
|
Catheter is percutaneous. For acute use only (up to 3 weeks). |
| VASCULAR |
FEMORAL A
|
Delivery,
Sample
Collection,
Infuse,
Chronic/
Acute
|
XL-ISC-
|
(S)
|
2,000
|
Port & catheter are placed subcutaneous. For chronic & acute use. The port is placed behind the ear for easy access. See [*] below. |
|
Acute
|
C9-58-90
|
(S) (P)
|
N/A
|
Catheter is percutaneous. For acute use only (up to 3 weeks). |
| VASCULAR |
FEMORAL V
|
Delivery, Sample Collection, Infuse, Chronic/Acute
|
XL-ISC-
|
(S)
|
2,000
|
Port & catheter are placed subcutaneous. For chronic & acute use. The port is placed behind the ear for easy access. See [*] below. |
|
Acute
|
C9-58-90
|
(S) (P)
|
N/A
|
Catheter is percutaneous. For acute use only (up to 3 weeks). |
| VASCULAR |
PORTAL
|
Delivery, Sample Collection, Infuse, Chronic/Acute
|
XL-ISC-
|
(S)
|
2,000
|
Port & catheter are placed subcutaneous. For chronic & acute use. The port is placed behind the ear for easy access. See [*] below. |
|
Acute
|
C9-58-90
|
(S) (P)
|
N/A
|
Catheter is percutaneous. For acute use only (up to 3 weeks). |
| VASCULAR |
HEPATIC
|
Delivery, Sample Collection, Infuse, Chronic/Acute
|
XL-ISC-
|
(S) (P)
|
2,000 |
Port & catheter are placed subcutaneous. For chronic & acute use. The port is placed behind the ear for easy access. See [*] below. |
|
Acute
|
C9-58-90
|
(S) (P)
|
N/A |
Catheter is percutaneous. For acute use only (up to 3 weeks). |
LATERAL
VENTRICLE |
|
Delivery, Sample Collection, Infuse, Chronic/Acute |
XL-ISC-
|
(S)
|
2,000 |
Port and catheter are placed subcutaneous. For chronic & acute use see [*] below |
| Acute |
C9-58-90 |
(S) (P) |
N/A |
Catheter is percutaneous. For acute use only (up to 3 weeks). |
| BILE DUCT |
|
Delivery, Sample Collection, Infuse, Chronic/Acute |
BDS-5 |
(P) SPECIAL |
1,500 |
Dual port, single port & catheter are placed subcutaneous. For chronic & acute usw. By injecting into the single port, the valve, at the common duct, is occluded. One side of the dual port can be used to collect bile & the other to inject fluids toward the duodenum. The BDS-5 systems have been used as long as 2 years. See [*] below. |
| BLADDER |
|
Delivery, Sample Collection, Infuse, Chronic/Acute |
XL-ISC- |
URI-4 (S)
|
2,000 |
Port and URI-4 catheter are placed percutaneous. Beside injecting & collecting system is also used for creating pressures. Catheter is made with soft high purity med. grade silicone to reduce irritation of the mucosa wall. Catheter has multiple holes therefore less possibility of catheter blockage. See [*] below. |
| BLADDER |
|
Delivery, Sample Collection, Infuse, Acute |
URI-4 |
(S) SPECIAL
|
N/A |
Catheter is percutaneous. For acute use only (up to 3 weeks). Catheter is made with soft high purity med. grade silicone to reduce irritation of the mucosa wall. Catheter has multiple holes therefore less possibility of catheter blockage. |
| URETHRA |
|
Delivery, Sample Collection, Infuse, Acute |
C9-58-90S |
(S) SPECIAL |
N/A |
Catheter is percutaneous. For acute use only (up to 3 weeks). Catheter is made with soft high purity med. grade silicone to reduce irritation of the mucosa wall. Catheter has multiple holes therefore less possibility of catheter blockage. |
| LYMPHATIC DUCT |
|
Delivery, Sample Collection, Infuse, Chronic/Acute |
XL-ISC- |
(S) (P) SPECIAL |
2,000 |
Port & catheter are placed subcutaneous. For chronic & acute use. See [*] below. |
*DaVINCI's ports and catheter systems[1] implanted subcutaneously are ideal for chronic and acute use. Due to our unique designs our implanted systems reduce occlusion, infection, saroma & necrosis. Our port and catheter systems maintain internal pressures, which increase longevity and maintain patency (greatly reducing occlusion, and obstruction of catheter). When system is locked with heparin & saline solution internal pressures reduce the possibility of back flow into the tip of the catheter. Through extensive engineering our systems are designed for easy use, longevity and bio-compatibility. DaVINCI is continually researching new designs to improve systems for our clients' specifications and needs. We welcome all inquiries.
DaVINCI also provides "Dual Port Systems" (see Implantable Devices). Two or more systems, shown above, can be implanted simultaneously. All forms of Telemetry and many other systems also implanted.
[1] U.S. Pat. No. 5,848,989 |