Guinea Pigs
DEVICE
ACCESS TO:
USAGE
IMPLANTED
SYSTEM
CATHETER
POLYURETHANE
(P) AND/OR
SILICONE (S)
NUMBER OF PUNCTURES WITH NEEDLE
COMMENTS
VASCULAR
JUGULAR
Delivery,
Sample
Collection,
Infuse,
Chronic/
Acute
M-ISC-
(S) (P) SPECIAL
1,500
Port & catheter are placed subcutaneous. For chronic & acute use see [*] below.
Delivery, Sample Collection, Infuse,
Acute
C5-
(S) (P)
N/A
Catheter is percutaneous. For acute use only (up to 3 weeks).
VASCULAR
CAROTID
Delivery,
Sample
Collection,
Infuse,
Chronic/
Acute
M-ISC-
(S) (P) SPECIAL
1,500
Port and catheter are placed subcutaneous. For chronic & acute use see [*] below
Acute
C5-
(S) (P)
N/A
Catheter is percutaneous. For acute use only (up to 3 weeks).
VASCULAR
FEMORAL A
Delivery,
Sample
Collection,
Infuse,
Chronic/
Acute
M-ISC-
(S)
1,500
Port and catheter are placed subcutaneous. For chronic & acute use see [*] below.
Acute
C5-
(S) (P)
N/A
Catheter is percutaneous. For acute use only (up to 3 weeks).
VASCULAR
FEMORAL V
Delivery, Sample Collection, Infuse, Chronic/Acute
M-ISC-
(S)
1,500
Port and catheter are placed subcutaneous. For chronic & acute use see [*] below.
Acute
C5-
(S) (P)
N/A
Catheter is percutaneous. For acute use only (up to 3 weeks).
VASCULAR
PORTAL
Delivery, Sample Collection, Infuse, Chronic/Acute
M-ISC-
(S)
1,500
Port and catheter are placed subcutaneous. For chronic & acute use see [*] below
Acute
C5-
(S) (P)
N/A
Catheter is percutaneous. For acute use only (up to 3 weeks).
VASCULAR
HEPATIC
Delivery, Sample Collection, Infuse, Chronic/Acute
M-ISC-
(S) (P)
1,500 Port and catheter are placed subcutaneous. For chronic & acute use see [*] below
Acute
C5-
(S) (P)
N/A Catheter is percutaneous. For acute use only (up to 3 weeks).
LATERAL
VENTRICLE
Delivery, Sample Collection, Infuse, Chronic/Acute
M-ISC-
(S)
1,500 Port and catheter are placed subcutaneous. For chronic & acute use see [*] below
Acute C5- (S) (P) N/A Catheter is percutaneous. For acute use only (up to 3 weeks).
INTRATHECAL Delivery, Sample Collection, Infuse, Chronic/Acute M-ISC- (P) SPECIAL 1,500 Port and catheter are placed subcutaneous. For chronic & acute use see [*] below.
NEURO,
LATERAL
VENTRICAL
Delivery, Sample Collection, Infuse, Chronic/Acute S-ISC
(S) (P) SPECIAL
100 Port and catheter are placed subcutaneous. For chronic & acute use. "Dead space" of port & catheter is 0.009CC. See [*] below.
BILE DUCT Delivery, Sample Collection, Infuse, Acute C5- (S) (P) SPECIAL N/A Diameter & length of catheter will vary.
BLADDER Delivery, Sample Collection, Infuse, Chronic/Acute M-ISC-
URI-2 (S)
1,500 Port and URI-1 catheter are placed percutaneous. Beside injecting & collecting system is also used for creating pressures. Catheter is made with soft high purity med. grade silicone to reduce irritation of the mucosa wall. Catheter has multiple holes therefore less possibility of catheter blockage. See [*] below.
BLADDER Delivery, Sample Collection, Infuse, Chronic/Acute URI-2
(S) SPECIAL
N/A Catheter is percutaneous. For acute use only (up to 3 weeks). Catheter is made with soft high purity med. grade silicone to reduce irritation of the mucosa wall. Catheter has multiple holes therefore less possibility of catheter blockage.
URETHRA Delivery, Sample Collection, Infuse, Acute C5-S (S) SPECIAL N/A Catheter is percutaneous. For acute use only (up to 3 weeks). Catheter is made with soft high purity med. grade silicone to reduce irritation of the mucosa wall. Catheter has multiple holes therefore less possibility of catheter blockage.

*DaVINCI's ports and catheter systems[1] implanted subcutaneously are ideal for chronic and acute use. Due to our unique designs our implanted systems reduce occlusion, infection, saroma & necrosis. Our port and catheter systems maintain internal pressures, which increase longevity and maintain patency (greatly reducing occlusion, and obstruction of catheter). When system is locked with heparin & saline solution internal pressures reduce the possibility of back flow into the tip of the catheter. Through extensive engineering our systems are designed for easy use, longevity and bio-compatibility. DaVINCI is continually researching new designs to improve systems for our clients' specifications and needs. We welcome all inquiries.

DaVINCI also provides "Dual Port Systems" (see Implantable Devices). Two or more systems, shown above, can be implanted simultaneously. All forms of Telemetry and many other systems also implanted.

[1] U.S. Pat. No. 5,848,989